EE-79 PRODUCT APPLICATION
Data Sheet | Product Application

SEE MATERIAL SAFETY DATA SHEET BEFORE HANDLING THIS PRODUCT

SURFACE PREPARATION:
Steel surfaces: Not generally recommended.

Concrete surfaces should be degreased if oil and grease contamination is present. Degreased surface shall be high pressure washed, acid etched and high pressure washed again so surface is clean and free of all grease, oils and surface laitance. Sandblasting and/ scarification may be recommended depending on surface. Existing coatings should be abrasive blasted to clean concrete.

MIXING:
Thoroughly mix Activator into Base with drill with low speed paint paddle. Scrape sides and bottom to ensure complete mixing. My by Volume 2 parts Base to 1 part Activator or by Weight 100 grams Base to 47.3 grams Activator. Mix 2 to 3 minutes and apply immediately. If required, add ARCOR™ NonSkid at 1/2 lb/gal, mix for 2 minutes and apply immediately.

THINNING: If desired, thin with Ketone blend from 5% to 7.5% by volume.

APPLICATION:
Brush: use medium to stiff bristle of sufficient quality that bristles do not pull out and stick in coating. Trim or tape to >1" nap.
Roller: use good quality 1/8" nap, 1/4" on concrete.
Squeegee: use plastic or hard rubber.

APPLICATION TEMPERATURE:
Material: Keep between 55 to 95ºF (13 to 35ºC). Substrate: Keep between 45 to 105ºF (7 to 40ºC). The difference in temperature of the substrate and the coating should never exceed 10ºF (5ºC). Substrate shall be a minimum of 5ºF(3ºC) above dew point. Do not use below 50ºF(8ºC).

OVERCOAT/CURE TIME:
By Brush, Roller or Squeegee recoat between 5 to 6 hours at 77ºF (25ºC)
Full cure in 72 hours @ 72ºF.

CLEAN UP: M.E.K. or similar.

WARNING: Base contains epoxy resin. Activator contains alkaline amines, a strong sensitizer. May cause skin irritation, sensitization or other allergic responses. Use with good ventilation, particularly if heated or sprayed. Prevent all contact with skin or eyes. Wear protective clothing, goggles, gloves or barrier creams. Keep containers closed when not in use. Wash thoroughly after handling. In case of skin contact immediately wash with soap and water. In case of eye contact, flush with water for 15 minutes. If irritation persists seek medical attention.