EE-79 PRODUCT
APPLICATION
Data
Sheet | Product Application
SEE
MATERIAL
SAFETY DATA SHEET BEFORE HANDLING THIS PRODUCT
SURFACE PREPARATION:
Steel surfaces: Not generally recommended.
Concrete surfaces should be
degreased if oil and grease contamination is present. Degreased
surface shall be high pressure washed, acid etched and high
pressure washed again so surface is clean and free of all
grease, oils and surface laitance. Sandblasting and/
scarification may be recommended depending on surface. Existing
coatings should be abrasive blasted to clean concrete.
MIXING:
Thoroughly mix Activator into Base with drill with low speed
paint paddle. Scrape sides and bottom to ensure complete mixing.
My by Volume 2 parts Base to 1 part Activator or by Weight 100
grams Base to 47.3 grams Activator. Mix 2 to 3 minutes and apply
immediately. If required, add ARCOR™ NonSkid at 1/2 lb/gal, mix
for 2 minutes and apply immediately.
THINNING: If desired, thin
with Ketone blend from 5% to 7.5% by volume.
APPLICATION:
Brush: use medium to stiff bristle of sufficient quality that
bristles do not pull out and stick in coating. Trim or tape to
>1" nap.
Roller: use good quality 1/8" nap, 1/4" on concrete.
Squeegee: use plastic or hard rubber.
APPLICATION TEMPERATURE:
Material: Keep between 55 to 95ºF (13 to 35ºC). Substrate: Keep
between 45 to 105ºF (7 to 40ºC). The difference in temperature
of the substrate and the coating should never exceed 10ºF (5ºC).
Substrate shall be a minimum of 5ºF(3ºC) above dew point. Do not
use below 50ºF(8ºC).
OVERCOAT/CURE TIME:
By Brush, Roller or Squeegee recoat between 5 to 6 hours at 77ºF
(25ºC)
Full cure in 72 hours @ 72ºF.
CLEAN UP:
M.E.K. or
similar.
WARNING: Base contains
epoxy resin. Activator contains alkaline amines, a strong
sensitizer. May cause skin irritation, sensitization or other
allergic responses. Use with good ventilation, particularly if
heated or sprayed. Prevent all contact with skin or eyes. Wear
protective clothing, goggles, gloves or barrier creams. Keep
containers closed when not in use. Wash thoroughly after
handling. In case of skin contact immediately wash with soap and
water. In case of eye contact, flush with water for 15 minutes.