GENERIC TYPE: AMINE CURED 100% SOLIDS EPOXY/URETHANE CAULK.

REVISED 5/2013

DESCRIPTION AND RECOMMENDED USES: ARCOR™ Arcthane is a high elongation, elastomeric, hybridized epoxy/urethane. It is ideally suited for expansion joint sealing and crack repair, and it is completely compatible with epoxy coatings. The urethane aspect delivers a tough, flexible resilience while the epoxy aspect provides improved water and chemical resistance and shelf stability. ARCOR™ Arcthane’s epoxy reactivity eliminates the moisture sensitivity and toxicity associated with traditional urethanes. ARCOR™ Arcthane is a light paste and is easily applied by squeegee or caulk gun up to 500 mils without slump.

FOR INDUSTRIAL USE ONLY

SPECIFICATION DATA:

 TEMPERATURE: Immersion service

Max.180ºF(82ºC); Spike to 200ºF(93ºC) 3 Hrs Min. 0ºF(-18ºC). Dry Max. 200ºF,Spike 225ºF.

 

CHEMICAL RESISTANCE:

Water:                                     Excellent

Alkalies:                                  Good

Inorganic Acids:                   Fair

Organic Acids:                      Fair

Organic Solvents:                Poor

 

SOLIDS BY VOLUME: 100%

VISCOSITY: Light Paste

POT LIFE: 55 MIN/Gal @ 72ºF

MIX RATIO: 2:1 by Volume (Base:Activator) 100 gm: 53 gm by weight

COLOR: Teal Blue

ABRASION: Good

FLEXIBILITY: Excellent Elongation 500%

FILM THICKNESS: Up to 500 mils/coat

APPLICATIONS: Water Box /Tube Sheet Expansion Joints, Crack Repair, Abrasion Protection, Cavitation Protection, Concrete.

SHELF LIFE: 5 Years at 55-95ºF (13-35ºC)

COVERAGE: Varies with thickness applied

WEIGHT PER GALLON: 11.1 lb (5.03 KG)

 

ORDER INFORMATION:

To place orders and/or obtain pricing information contact:

ARCOR Epoxy Inc. PO Box 273

South Dennis, MA 02660

TEL: 800-878-9593; FAX: 888-878-9593

Contact Us!

Manufacturer makes no warranty either expressed or implied including warranties of merchant ability or fitness for a particular purpose for this product. Under no circumstances will the manufacturer be liable for incidental, consequential or other damages, breach of warranty, strict liability, or any other theory arising out of use of this product.

APPLICATION SHEET

REVISED 5/2013

SEE MATERIAL SAFETY DATA SHEET BEFORE HANDLING THIS PRODUCT

 

SURFACE PREPARATION:

Steel surfaces are to be abrasive blasted with chloride free abrasive. Exterior applications to SSPC SP-6 commercial gray metal finish. Immersion applications to SSPC SP-6 white metal 3 to 5 mil profile. Grind all burrs, weld seems, radius sharp edges. Fresh blasted surfaces to be primed immediately with ARCOR™ S-30 Prime to prevent oxidation of surface.

Concrete surfaces should be degreased if oil and grease contamination is present. Degreased surface shall be high pres- sure washed, acid etched and high pressure washed again so surface is clean and free of all grease and oils and surface laitance. Existing coatings should be abrasive blasted to clean concrete. Prime with ARCOR™ ARCRETE(unfilled), ARCOR™ EE-71 or ARCOR™ EE-10.

MIXING:

Thoroughly mix Activator into Base with mixing stick or drill with low speed mixing blade scraping sides and bottom of container or mixing board. Mix by Volume 2 part Base to 1 part Activator. Or by weight 100 gm Base to 53 gm Activator. Mix thoroughly to produce an even colored and streak-free material.

THINNING:

Never thin.

APPLICATION:

Use heavy plastic squeegee, putty knife or caulk gun.

APPLICATION TEMPERATURE:

Material: Keep between 55 to 95ºF(17 to 35ºC). Substrate: Keep between 45 to 105ºF(7 to 40ºC). The difference in temperature of the substrate and the material should never exceed 10ºF(5ºC). Substrate shall be a minimum of 5ºF(3ºC) above dew point. Do not apply if relative humidity exceeds 90%. If necessary heat metal prior to surface preparation using electric heater or heat lamp. Never use gas, oil or kerosene heaters as they will leave a greasy residue on metal surface. For best results keep all material in warm area overnight(75ºF+, 24ºC) for ease of mixing. If necessary base component of material can be heated by microwave for 30-45 seconds for a 1 KG Base unit or by warm water bath. Heat activator by warm water bath only. If necessary let material cool before application.

OVERCOAT / CURE TIME:

Re-coat between 6 and 12 hours at 77ºF (25ºC).Add 1 day additional cure time for each 10ºF below 77ºF. Subtract 15 hours of cure time for each 10ºF above 77ºF. Full cure before immersion 72 hours at 77ºF. Force Cure: 12 hours at 120ºF (49ºC).

 

CLEAN UP: Clean tools immediately after use with M.E.K. or similar. Isopropyl Alcohol can be used in solvent restricted areas.

 

WARNING: Base contains epoxy resin. Activator contains alkaline amines, a strong sensitizer. May cause skin irritation, sensitization or other allergic responses. Use with good ventilation, particularly if heated or sprayed. Prevent all contact with skin or eyes. Wear protective clothing, goggles, gloves or barrier creams. Keep containers closed when not in use. Wash thoroughly after handling. In case of skin contact immediately wash with soap and water. In case of eye contact, flush with water for 15 minutes. If irritation persists seek medical attention.