ARCOR Header

Cast Iron Waterbox Repair

DOWNLOAD PDF

Case History #028 REV.04-97

Main condenser cast iron waterboxes were experiencing corrosion and metal loss in salt water service. Metal loss was severe adjacent to the Muntz Metal tubesheet where dissimilar metals set up a galvanic cell. A three-step coating system was installed to protect the cast iron substrate from further corrosion and erosion damage. The ARCOR™ system provides a barrier to protect the substrate from the salt water and acts as an insulator to eliminate the galvanic cell. Corroded surface inside waterbox. Abrasive-blasted interior. Top-coat of ARCOR S-30 Blue.