Channel Head Coating
DOWNLOAD PDF
Case History #025 REV.04-97
Carbon steel heat exchanger channel heads exposed to salt water developed pitting over the years to a point where metal loss became a concern. A three-coat system of ARCOR™ S-16 was installed to protect the substrate from the salt water. After abrasive blasting ARCOR™ S-16 was installed in three successive coats of White, Fuchsia and Blue at 15 mils each for a total dry film thickness of 45 mils. Application of first coat of ARCOR S-16.ARCOR S-16 second coat. Finished after three coats of ARCOR S-16.