Main Condenser
- Home
- English Homepage
- Case Histories
- Main Condenser

Main Condenser Coating
Case History #039 REV.04-97
LOCATION: South Ukraine Nuclear Power Plant Unit #1
PROBLEM:
This nuclear power plant had problems with a general leaking of the condenser at the tube to tubesheet joint. Continued sever scaling of the tube internals was causing a steep decline in heat transfer.
SOLUTION:
The unit has 116,000 9 meter, 26mm ID 95/4/1 CuNiFe Tubes and 24 Carbon Steel tubesheets at 25 M2 each. All tubes were to be cleaned and all tubesheets coated.
RESULTS:
This project was completed in April 1991 and has not required repair.
Related Links:
ARCOR S 30 Prime
ARCOR S 30
ARCOR TS-RB
More Information:
Contact Us
Call Our Offices
Previous
Next