GENERIC TYPE: AMINE CURED 100% SOLIDS EPOXY 3.6 NOVOLAC TOPCOAT
DESCRIPTION AND RECOMMENDED USES: ARCOR® EE-111 is a solvent free, high 3.6 functionality epoxy Novolac coating suitable for immersion and non-immersion service, particularly in aggressive chemical with elevated temperatures and high abrasion. ARCOR® EE-111 produces a tough, chemical resistant coating on ferrous and non-ferrous metals and concrete. Use of micro ceramic spheres gives high abrasion resistance while still allowing plural spray application for large scale projects . As a low viscosity 3.6 functionality epoxy Novolac ARCOR® EE-111 is suitable for hand or spray application at up to 25 mils per coat. Immersion Temperatures to 350ºF(162ºC). Excellent for Methanol, Glacial Acetic Acid, Methylene Chloride, Hydrochloric Acid, Nitric Acid, Sulphuric Acid.
FOR INDUSTRIAL USE ONLY
SPECIFICATION DATA:
TEMPERATURE: Immersion service
Max. 350ºF (162ºC); Spike to 400ºF (190ºC) With force cure at 250ºF, 6 Hrs
SOLIDS BY VOLUME: 100%
VISCOSITY: 35,000-50,000 cps
POT LIFE: 15 MIN/150gr @ 72ºF
MIX RATIO: 2:1 by Volume (Base:Activator) 100 gm: 60 gm by weight
COLOR: Gray
ABRASION: Very Good
FILM THICKNESS: 20-80 mils(.51-2.04 mm)/coat Splash: 1-2 coats, Immersion: 1-2 coats (up to 80 mils in one coat)
Flexibility: Very Good Excellent with Polyester Mat; 1.5 oz/ft² (5. KG/M²)
Applications: Aggressive Chemical Tank Linings and Secondary Containment Areas, FGD; Ducts, Mix Zones, I.D. Fans, Scrubbers.
Excellent when force cure is not available.
SHELF LIFE: 5 Years at 55-95ºF (13-35ºC)
COVERAGE: 20-80 ft²(1.9-7.5 M²)/gal/coat
WEIGHT PER GALLON: 12 lbs (5.44 KG)
Manufacturer, Novolac Epoxy Technologies Inc., makes no warranty either expressed or implied including warranties of merchantability or fitness for a particular purpose for this product. Under no circumstances will the manufacturer be liable for incidental, consequential or other damages, breach of warranty, strict liability, or any other theory arising out of use of this product. The information and or recommendations contained herein are based on standard Product and are proprietary and furnished solely for the use of our customers. This information is provided in good faith and believed to be true and accurate as of the date/version of this document. As the manufacturer has no control over the use conditions or application process of the parties using this product, the manufacturer cannot accept responsibility for loss, injury or other damages resulting from the use of the Product or this or any other information provided by the manufacturer. Therefore, no guarantees of any kind, expressed or implied, are made by the manufacturer, Novolac Epoxy Technologies Inc., regarding this, or any, product manufactured by them or any contracted or licensed manufacturer. ARCOR® epoxy products do not provide structural integrity or improvement. They are only used to provide protection from corrosion, wear, abrasion and chemical attack on a given substrate and only to the extent provided for in the Data Sheets, Technical Data Sheets, Safety Data Sheets and any other information as supplied in writing directly from manufacturers technical support.
APPLICATION SHEET
REVISED 6/2013
SEE MATERIAL SAFETY DATA SHEET BEFORE HANDLING THIS PRODUCT
SURFACE PREPARATION: Steel surfaces are to be abrasive blasted with chloride free abrasive. Exterior applications to SSPC SP-10 Near White metal finish. Immersion applications to SSPC SP-5 White metal 3 to 5 mil profile. Grind flat all burrs, weld seams, radius sharp edges. Fresh blasted ferrous surfaces to be primed immediately with ARCOR® EE80 or EE-111 Prime to prevent oxidation of surface. Concrete surfaces should be degreased if oil and grease contamination is present. Degreased surface shall be high pressure washed, acid etched and high pressure washed again so surface is clean and free of all grease, oils and surface laitance. Existing coatings should be abrasive blasted to clean concrete. Prime with ARCOR® EE-111 Prime.
MIXING: Thoroughly mix Activator into Base with mixing stick or drill with low speed mixing blade scraping sides and bottom of container or mixing board. Mix by Volume 2 parts Base to 1 part Activator. Or by weight 100 grams base to 60 grams activator. Mix thoroughly to produce an even colored and streak-free material.
THINNING: Never thin.
APPLICATION: All spray equipment should employ traps to prevent water and oil from contaminating coating
Brush: medium to stiff bristle of sufficient quality that bristles do not pull out and stick in coating. Trim or tape to <1” nap. Roller: good quality 1/8”-1/4” nap.
Plural Spray: .529-.531 tip, 2,500-3,500 PSI, Heat to 150ºF Base, 150ºF Activator, Line Heat @ 190ºF, Hose Heat @ 150ºF. Use 30 mesh screens, 2-3 in-line static mixers. Keep additional material in hotbox @ 120-140ºF.
Airless Spray: Not Recommended Conventional Spray: Not Recommended
APPLICATION TEMPERATURE: Material: Keep between 55 to 95ºF (17 to 35ºC). Substrate: Keep between 45 to 105ºF (7 to 40ºC). The difference in temperature of the substrate and the material should never exceed 10ºF (5ºC). Substrate shall be a minimum of 5ºF (3ºC) above dew point. Do not apply if relative humidity exceeds 90%. If necessary heat metal prior to surface preparation using electric heater or heat lamp. Never use gas, oil or kerosene heaters as they will leave a greasy residue on metal surface. For best results keep all material in warm area overnight (75ºF+, 24ºC) for ease of mixing. If necessary base component of material can be heated by microwave for 30-45 seconds for a 1 KG Base unit or by warm water bath. Heat activator by warm water bath only. If necessary let material cool before application.
OVERCOAT/CURE TIME: By brush, roller or squeegee re-coat while material is still soft, but tack-free, between 2-8 hours at 77ºF (25ºC). If over- coat window is exceeded abrade surface with course sandpaper, grinder or brush blast & wipe thoroughly with MEK or Acetone. By spray application re-coat between 1-4 hours at 77ºF. Full cure before immersion 72 hours at 77ºF.
Add 2 hours additional cure time for each 10ºF below 77ºF. Force Cure with heat for best performance for 2 hours at 250ºF(121ºC), 8 hours at 120ºF (49ºC);
CLEAN UP: Clean tools immediately after use with M.E.K., Acetone, 98+% Isopropyl Alcohol or similar
WARNING: Base contains epoxy resin. Activator contains alkaline amines, a strong sensitizer. May cause skin irritation, sensitization or other allergic responses. Use with good ventilation, particularly if heated or sprayed. Prevent all contact with skin or eyes. Wear protective clothing, goggles, gloves or barrier creams. Keep containers closed when not in use. Wash thoroughly after handling. In case of skin contact immediately wash with soap and water. In case of eye contact, flush with water for 15 minutes. If irritation persists seek medical attention. Consult the Product Safety Data Sheets (SDS) BEFORE USE!
The information and or recommendations contained herein are based on standard Product and are proprietary and furnished solely for the use of our customers. This information is provided in good faith and believed to be true and accurate as of the date/version of this document. As the manufacturer has no control over the use conditions or application process of the parties using this product, the manufacturer cannot accept responsibility for loss, injury or other damages resulting from the use of the Product or this or any other information provided by the manufacturer. Therefore, no guarantees of any kind, expressed or implied, are made by the manufacturer, Novolac Epoxy Technologies Inc., regarding this, or any, product manufactured by them or any contracted or licensed manufacturer.

Are you interested in this product?
Want to know more?
To place orders and/or obtain pricing information contact or call our offices below:
Manufacturer makes no warranty either expressed or implied including warranties of merchantability or fitness for a particular purpose for this product. Under no circumstances will the manufacturer be liable for incidental, consequential or other damages, breach of warranty, strict liability, or any other theory arising out of use of this product. ARCOR® epoxy products do not provide structural integrity or improvement. They are only used to provide protection from corrosion, wear, abrasion and chemical attack on a given substrate and only to the extent provided for in the Data Sheets, Technical Data Sheets, Safety Data Sheets and any other information as supplied in writing directly from manufacturers technical support.