ARCOR EE-72

ARCOR Header

ARCOR EE-72

GENERIC TYPE: AMINE CURED 100% SOLIDS EPOXY TOPCOAT FOR CONCRETE

DESCRIPTION AND RECOMMENDED USES: ARCOR™ EE-72 is a solvent free, high functionality epoxy Novolac coating suitable as a self-leveling flooring, particularly in aggressive environments with exposure to acids and alkalis. ARCOR™ EE-72 produces a tough, chemical resistant coating on concrete, ferrous and non-ferrous metals. Use of Reactive Flexibilizing agents gives excellent flexibility without sacrificing chemical resistance making EE-72 ideal for concrete or metal floors with thermal, design or structural stress, without the need for fiberglass mat reinforcement. High abrasion resistance in an easy to clean surface. ARCOR™ EE-72 is suitable for hand or spray application at up to 100 mils per coat.

FOR INDUSTRIAL USE ONLY

SPECIFICATION DATA:

TEMPERATURE: Immersion service

Max.265ºF (130ºC); Dry to 400ºF (3 Hrs)

ABRASION:  Very Good

FILM THICKNESS: 20 -100 mils (.51-2.55 mm)/coat

Splash: 1 coats, Immersion: 2-3 coats

FLEXIBILITY: Good, Excellent with Polyester or Fiberglass Mat; 1.5 oz/fl2 (.5 KG/M2)

APPLICATIONS: Aggressive Chemical Secondary Containment Areas, Aggressive Industrial Floors, High Impact Flooring.

SOLIDS BY VOLUME: 100%

VISCOSITY: 2,000-3,000 cps

POT LIFE: 35 MIN/KG @ 72ºF

MIX RATIO: 2:1 by Volume (Base: Activator) 100 gm: 40 gm by weight

COLOR: Gray, Blue (special order colors available)

SHELF LIFE: 5 Years at 55-95ºF (13-35ºC)

COVERAGE: 80 ft2 (1.9-7.5 M2)/ gal / coat

WEIGHT PER GALLON: 12.5 lbs (5.7 KG)

Manufacturer, Novolac Epoxy Technologies Inc., makes no warranty either expressed or implied including warranties of merchantability or fitness for a particular purpose for this product. Under no circumstances will the manufacturer be liable for incidental, consequential or other damages, breach of warranty, strict liability, or any other theory arising out of use of this product. The information and or recommendations contained herein are based on standard Product and are proprietary and furnished solely for the use of our customers. This information is provided in good faith and believed to be true and accurate as of the date/version of this document. As the manufacturer has no control over the use conditions or application process of the parties using this product, the manufacturer cannot accept responsibility for loss, injury or other damages resulting from the use of the Product or this or any other information provided by the manufacturer. Therefore, no guarantees of any kind, expressed or implied, are made by the manufacturer, Novolac Epoxy Technologies Inc., regarding this, or any, product manufactured by them or any contracted or licensed manufacturer. ARCOR® epoxy products do not provide structural integrity or improvement. They are only used to provide protection from corrosion, wear, abrasion and chemical attack on a given substrate and only to the extent provided for in the Data Sheets, Technical Data Sheets, Safety Data Sheets and any other information as supplied in writing directly from manufacturers technical support.

APPLICATION SHEET

REVISED 5/2017

SEE MATERIAL SAFETY DATA SHEET BEFORE HANDLING THIS PRODUCT

SURFACE PREPARATION:
Steel surfaces are to be abrasive blasted with chloride free abrasive. Exterior applications to SSPC SP-10 Near White metal finish. Immersion applications to SSPC SP-5 White metal 3 to 5 mil profile. Grind flat all burrs, weld seams, radius sharp edges. Fresh blasted ferrous surfaces to be primed immediately with ARCOR™ EE-72 or ARCOR™ EE-80 to prevent oxidation of surface.

Concrete surfaces should be degreased if oil and grease contamination is present. Degreased surface shall be high pressure washed. Loose existing coatings should be chipped & ground to remove then entire floor is to be abrasive blasted to remove all existing coating, mastics and laitenance. Clean & grind all cracks & expansion joints. Thoroughly sweep & vacuum.

Prime entire floor with ARCOR™ EE-80, EE-10 or EE-72.

MIXING:
Thoroughly mix Activator into Base with mixing stick or drill with low speed mixing blade scraping sides and bottom of container or mix• ing board. Mix by Volume 2 parts Base to 1-part Activator. Or by weight 100 grams base to 40 grams activator. Mix thoroughly to pro• duce an even colored and streak-free material.

THINNING: Never thin.

APPLICATION:
Squeegee: heavy duty rubber ‘notched’ squeegee
Roller: good quality 1” nap.
Plural Spray: .017-.025 tip, 3,000-3,500 PSI, Heat to 110°F Base, 100°F Activator.
Airless Spray: .019-.027 tip, 3,000-3,500 PSI (45: 1). (Caution: Short Pot-Life)
Conventional Spray: Not Recommended unless experience user..

All spray equipment should employ traps to prevent water and oil from contaminating coating and screens to prevent particulate con•tamination.

APPLICATION TEMPERATURE:
Material: Keep between 55 to 95°F (17 to 35°C). Substrate: Keep between 45 to 105°F (7 to 40°C). The difference in temperature of the substrate and the material should never exceed 10°F(5°C). Substrate shall be a minimum of 5°F(3°C) above dew point. Do not apply if relative humidity exceeds 90%. If necessary, heat metal prior to surface preparation using electric heater or heat lamp. Never use gas, oil or kerosene heaters as they will leave a greasy residue on metal surface. For best results keep all material in warm area overnight (75°F+, 24°C) for ease of mixing. If necessary, base component of material can be heated by microwave for 30-45 seconds for a 1 KG Base unit or by warm water bath. Heat activator by warm water bath only. If necessary, let material cool before application.

OVERCOAT / CURE TIME: 
By brush, roller or squeegee recoat while material is still soft, but tack-free, between 6-14 hours at 77°F(25°C). If overcoat window is exceeded abrade surface with course sandpaper, grinder or brush blast. By spray application recoat between 2-14 hours at 77°F. Full cure before immersion 72 hours at 77°F. Add 30 hours additional cure time for each 10°F below 77°F. Subtract 12 hours of cure time for each 10°F above 77°F. Force Cure with heat for best performance for 4 hours at 200°F(93°C), 12 hours at 150°F(66°C).

CLEAN UP:
Clean tools immediately after use with M.E.K., Acetone or similar.98+% isopropyl Alcohol can be used in solvent restricted areas.

Want to see if ARCOR Products are what you need, or just want to know more? 

To place orders and/or obtain pricing information contact or call our offices below:
Manufacturer makes no warranty either expressed or implied including warranties of merchantability or fitness for a particular purpose for this product. Under no circumstances will the manufacturer be liable for incidental, consequential or other damages, breach of warranty, strict liability, or any other theory arising out of use of this product. ARCOR® epoxy products do not provide structural integrity or improvement. They are only used to provide protection from corrosion, wear, abrasion and chemical attack on a given substrate and only to the extent provided for in the Data Sheets, Technical Data Sheets, Safety Data Sheets and any other information as supplied in writing directly from manufacturers technical support.