GENERIC TYPE: AMINE CURED 100% SOLIDS EPOXY REBUILD
DESCRIPTION AND RECOMMENDED USES: ARCOR™ EE-91 is a solvent free epoxy rebuilding compound designed for corrosion and abrasion protection of condensers and heat exchangers. EE-91 is excellent for immersion in all water environments, Salt, Brackish, Potable. EE-91 will fully cure in water immersion. ARCOR™ EE-91 can be applied up to 500 mils without slump. EE-91 is; NSF certified for portable water; USDA for incidental Food Contact in Meat & Poultry Production; FDA Guideline CFR 21 Section 175.300 listed for repeated food contact use.
FOR INDUSTRIAL USE ONLY
SPECIFICATION DATA:
TEMPERATURE: Immersion service
Max. 120ºF ; Dry to 200ºF
SOLIDS BY VOLUME: 100%
VISCOSITY: Putty
POT LIFE: 35 MIN / KG @ 72ºF
MIX RATIO: 2:1 by Volume (Base:Activator) 100 gm: 48 gm by Weight
COLOR: Grey
ABRASION: Very Good
FILM THICKNESS: up to 500 mils vertical
FLEXIBILITY: Good Fair Flexural Strength 10,000 psi
APPLICATIONS: Condensers, Heat Exchangers, Circ. Pipe, Water Screens, Pumps, Impellers, Filters, Valves, Hydro Wheels, Tank Linings, Ion Exchange Filters.
SHELF LIFE: 5 Years at 55-95ºF (13-35ºC)
COVERAGE: varies with thickness applied
WEIGHT PER GALLON: 12 lbs (5.44 KG)
Manufacturer, Novolac Epoxy Technologies Inc., makes no warranty either expressed or implied including warranties of merchantability or fitness for a particular purpose for this product. Under no circumstances will the manufacturer be liable for incidental, consequential or other damages, breach of warranty, strict liability, or any other theory arising out of use of this product. The information and or recommendations contained herein are based on standard Product and are proprietary and furnished solely for the use of our customers. This information is provided in good faith and believed to be true and accurate as of the date/version of this document. As the manufacturer has no control over the use conditions or application process of the parties using this product, the manufacturer cannot accept responsibility for loss, injury or other damages resulting from the use of the Product or this or any other information provided by the manufacturer. Therefore, no guarantees of any kind, expressed or implied, are made by the manufacturer, Novolac Epoxy Technologies Inc., regarding this, or any, product manufactured by them or any contracted or licensed manufacturer. ARCOR® epoxy products do not provide structural integrity or improvement. They are only used to provide protection from corrosion, wear, abrasion and chemical attack on a given substrate and only to the extent provided for in the Data Sheets, Technical Data Sheets, Safety Data Sheets and any other information as supplied in writing directly from manufacturers technical support.
APPLICATION SHEET
REVISED 5/2013
SEE MATERIAL SAFETY DATA SHEET BEFORE HANDLING THIS PRODUCT
SURFACE PREPARATION: Metal surfaces are to be cleaned and degreased then abrasive blasted with chloride free abrasive. Exterior applications to SSPC SP-10 near white metal finish minimum 3 mil profile. Immersion applications to SSPC SP-5 White Metal, 3-5 mil profile. Grind flat all burrs, weld seams, radius sharp edges. Fresh blasted surfaces to be rebuilt as quickly as possible
to prevent oxidation of the surface. For larger surface areas with ferrous metals apply a primer layer of ARCOR™ S-30 Prime to prevent oxidation of the surface and allow time for proper rebuilding of the damaged area.
Concrete surfaces should be degreased if oil and grease contamination is present. Degreased surface shall be high pres- sure washed, acid etched and high pressure washed again so surface is clean and free of all grease, oils and surface laitance. Existing coatings should be abrasive blasted to clean concrete. Prime with ARCOR™ EE-10
MIXING: Thoroughly mix Activator into Base with mixing stick or drill with low speed mixing blade scraping sides and bottom of container or mixing board. Mix by Volume 2 parts Base to 1 part Activator. Or by weight 100 grams base to 48 grams activator. Mix thoroughly to produce an even colored, streak-free material.
THINNING: Never thin.
APPLICATION: Use heavy plastic squeegee or putty knife. Work material into profile of substrate to achieve maximum adhesion and to remove any entrapped air. Contour to correct form with putty knife or plastic applicator. If mold or form is used, coat its surface with a release agent to prevent adhesion of the material. Machining is possible using carbide tipped tools.
Grinding is possible if done within 14 hours of application at 77ºF, 25ºC (add 1-1/2 hour for each 10ºF below 77º, subtract 1 hour for each 10º above 77ºF). Large holes and cracks can be bridged with glass or metal cloth.
APPLICATION TEMPERATURE: Material: Keep between 55 to 95ºF (17 to 35ºC). Substrate: keep between 45 to 105ºF (7 to 40ºC). the difference in temperature of the substrate and the material should never exceed 10ºF, 5ºC. Substrate shall be a minimum of 5ºF (3ºC) above dew point. Do not apply if relative humidity exceeds 90%. If necessary heat the metal prior to surface preparation using electric heater or heat lamp. Never use gas, oil or kerosene heaters as they will leave a greasy residue on metal surface. For best results keep all material in warm area overnight (75ºF+) for ease of mixing. If necessary Base component of material can be heated by microwave for 30-45 seconds for a 1 KG Base unit or by warm water bath. Heat activated by warm water bath only. If necessary let material cool before application.
OVERCOAT / CURE TIME: Re-coat while material is still soft, between 6 to 14 hours at 77ºF, 25ºC. If overcoat window is exceeded abrade surface with course sandpaper, grinder or brush blast. Full cure before immersion 72 hours at 77ºF. Add 1 day additional cure time for every 10ºF below 77ºF. Subtract 15 hours of cure time for each 10ºF above 77ºF. Force cure with heat for best performance for 1 hour at 200ºF, 93ºC, 12 hours at 120ºF at 120ºF, 49ºC.
CLEAN UP: Clean tools immediately after use with M.E.K., Acetone, 98+% Isopropyl Alcohol or similar
WARNING: Base contains epoxy resin. Activator contains alkaline amines, a strong sensitizer. May cause skin irritation, sensitization or other allergic responses. Use with good ventilation, particularly if heated or sprayed. Prevent all contact with skin or eyes. Wear protective clothing, goggles, gloves or barrier creams. Keep containers closed when not in use. Wash thoroughly after handling. In case of skin contact immediately wash with soap and water. In case of eye contact, flush with water for 15 minutes. If irritation persists seek medical attention. Consult the Product Safety Data Sheets (SDS) BEFORE USE!
The information and or recommendations contained herein are based on standard Product and are proprietary and furnished solely for the use of our customers. This information is provided in good faith and believed to be true and accurate as of the date/version of this document. As the manufacturer has no control over the use conditions or application process of the parties using this product, the manufacturer cannot accept responsibility for loss, injury or other damages resulting from the use of the Product or this or any other information provided by the manufacturer. Therefore, no guarantees of any kind, expressed or implied, are made by the manufacturer, Novolac Epoxy Technologies Inc., regarding this, or any, product manufactured by them or any contracted or licensed manufacturer.

Are you interested in this product?
Want to know more?
To place orders and/or obtain pricing information contact or call our offices below:
Manufacturer makes no warranty either expressed or implied including warranties of merchantability or fitness for a particular purpose for this product. Under no circumstances will the manufacturer be liable for incidental, consequential or other damages, breach of warranty, strict liability, or any other theory arising out of use of this product. ARCOR® epoxy products do not provide structural integrity or improvement. They are only used to provide protection from corrosion, wear, abrasion and chemical attack on a given substrate and only to the extent provided for in the Data Sheets, Technical Data Sheets, Safety Data Sheets and any other information as supplied in writing directly from manufacturers technical support.