GENERIC TYPE: AMINE CURED 100% SOLIDS EPOXY REBUILDING COMPOUND
DESCRIPTION AND RECOMMENDED USES: ARCOR™ EE 99 is a solvent free two-component, moisture insensitive epoxy rebuild designed as an emergency repair or bonding material for metals, glass, concrete, or wood. ARCOR™ EE-99 sets in 5 minutes and can get put in service within 1 hour regardless of temperature. ARCOR™ EE-99 has good resistance in a wide variety of chemical environments and has heat resistance to 450ºF. ARCOR™ EE-99 has an easy to use 1:1 mix ratio and can be applied overhead or vertically.
FOR INDUSTRIAL USE ONLY
SPECIFICATION DATA:
TEMPERATURE: Immersion service
Max. 200ºF (93ºC) ; Dry to 450ºF (232ºC)
ABRASION: Excellent
FLEXIBILITY: Fair
BOND STRENGTH: 3,000 psi @ 2 hours 3,600 psi @ 24 hours
FILM THICKNESS: up to 1000 mils/coat
APPLICATIONS: Repair burst pipes, tanks, pumps and the like which contain liquids or gases. Use for bonding Dissimilar Metals. Use for Concrete, Metal, Glass, Wood.
SOLIDS BY VOLUME: 100%
VISCOSITY: Paste
POT LIFE: 3-5 MIN @ 72ºF
DENSITY: 1.48
MIX RATIO: 1:1 by Volume (Base:Activator) 100 gm: 119 gm by Weight
COLOR: Gray
SHELF LIFE: 5 Years at 55-95ºF (13-35ºC)
COVERAGE: varies with thickness applied
WEIGHT PER GALLON: 12.4 lbs (6.53 KG)
Manufacturer, Novolac Epoxy Technologies Inc., makes no warranty either expressed or implied including warranties of merchantability or fitness for a particular purpose for this product. Under no circumstances will the manufacturer be liable for incidental, consequential or other damages, breach of warranty, strict liability, or any other theory arising out of use of this product. The information and or recommendations contained herein are based on standard Product and are proprietary and furnished solely for the use of our customers. This information is provided in good faith and believed to be true and accurate as of the date/version of this document. As the manufacturer has no control over the use conditions or application process of the parties using this product, the manufacturer cannot accept responsibility for loss, injury or other damages resulting from the use of the Product or this or any other information provided by the manufacturer. Therefore, no guarantees of any kind, expressed or implied, are made by the manufacturer, Novolac Epoxy Technologies Inc., regarding this, or any, product manufactured by them or any contracted or licensed manufacturer. ARCOR® epoxy products do not provide structural integrity or improvement. They are only used to provide protection from corrosion, wear, abrasion and chemical attack on a given substrate and only to the extent provided for in the Data Sheets, Technical Data Sheets, Safety Data Sheets and any other information as supplied in writing directly from manufacturers technical support.
APPLICATION SHEET
REVISED 5/2013
SEE MATERIAL SAFETY DATA SHEET BEFORE HANDLING THIS PRODUCT
SURFACE PREPARATION: For best results clean area to be repaired to remove loose dirt, scale and oils. Use MEK or a similar solvent and a degreaser if oils are present. If possible sand or grind the area with course paper or disk.
MIXING: Thoroughly mix Activator into Base with mixing stick scraping sides and bottom of container or mixing board. Mix by volume 1 parts Base to 1 part Activator. Or by weight 100 grams Base to 119 grams Activator. Mix thoroughly to produce an even colored, streak-free material.
THINNING: If desired, thin with Kelone blend from 5% to 7.5% by volume
APPLICATION: Use heavy plastic squeegee or putty knife. Work material into profile of substrate to achieve maximum adhesion and to remove any entrapped air. Contour to correct form with putty knife or plastic applicator. If mold or form is used, coat its surface with a release agent to prevent adhesion of the material. Machining is possible using diamond tipped tools only. Sanding/Grinding is possible if done within 1 hour of application at 77ºF, 25ºC. Caution: Material cures rapidly. Use only the quantity of material which can be easily applied within 4 to 5 minutes. Spreading mixed material on a mixing board or other flat surface will extend the working life. Large holes and cracks can be bridged with glass or metal cloth.
APPLICATION TEMPERATURE: Material: Keep between 55 to 95ºF (17 to 35ºC). Substrate: keep between 45 to 105ºF (7 to 40ºC). The difference in temperature of the substrate and the material should never exceed 10ºF, 5ºC. Substrate shall be a minimum of 5ºF (3ºC) above dew point. Do not apply if relative humidity exceeds 90%. If necessary heat the metal prior to surface preparation using electric heater or heat lamp. Never use gas, oil or kerosene heaters as they will leave a greasy residue on metal surface. For best results keep all material in warm area overnight (75ºF+) for ease of mixing. If necessary Base component of material can be heated by microwave for 30-45 seconds for a 1 KG Base unit or by warm water bath. Heat activated by warm water bath only. If necessary let material cool before application. Caution: Material cures rapidly. Use only the quantity of material which can be easily applied within 4 to 5 minutes. Heating will accelerate cure time.
OVERCOAT / CURE TIME: Re-coat as soon as possible while material is still soft, within 1 hour at 77ºF, 25ºC. If overcoat window is exceeded abrade surface with course sandpaper, grinder or brush blast. Full cure before immersion 45 minutes at 77ºF. Add 10 minutes additional cure time for each 10ºF below 77ºF. Subtract 15 minutes of cure time for each 10ºF above 77ºF.
CLEAN UP: Clean tools immediately after use with M.E.K., Acetone, 98+% Isopropyl Alcohol or similar
WARNING: Base contains epoxy resin. Activator contains alkaline amines, a strong sensitizer. May cause skin irritation, sensitization or other allergic responses. Use with good ventilation, particularly if heated or sprayed. Prevent all contact with skin or eyes. Wear protective clothing, goggles, gloves or barrier creams. Keep containers closed when not in use. Wash thoroughly after handling. In case of skin contact immediately wash with soap and water. In case of eye contact, flush with water for 15 minutes. If irritation persists seek medical attention. Consult the Product Safety Data Sheets (SDS) BEFORE USE!
The information and or recommendations contained herein are based on standard Product and are proprietary and furnished solely for the use of our customers. This information is provided in good faith and believed to be true and accurate as of the date/version of this document. As the manufacturer has no control over the use conditions or application process of the parties using this product, the manufacturer cannot accept responsibility for loss, injury or other damages resulting from the use of the Product or this or any other information provided by the manufacturer. Therefore, no guarantees of any kind, expressed or implied, are made by the manufacturer, Novolac Epoxy Technologies Inc., regarding this, or any, product manufactured by them or any contracted or licensed manufacturer.

Are you interested in this product?
Want to know more?
To place orders and/or obtain pricing information contact or call our offices below:
Manufacturer makes no warranty either expressed or implied including warranties of merchantability or fitness for a particular purpose for this product. Under no circumstances will the manufacturer be liable for incidental, consequential or other damages, breach of warranty, strict liability, or any other theory arising out of use of this product. ARCOR® epoxy products do not provide structural integrity or improvement. They are only used to provide protection from corrosion, wear, abrasion and chemical attack on a given substrate and only to the extent provided for in the Data Sheets, Technical Data Sheets, Safety Data Sheets and any other information as supplied in writing directly from manufacturers technical support.