GENERIC TYPE: AMINE CURED 100% SOLIDS NOVOLAC, TOPCOAT
DESCRIPTION AND RECOMMENDED USES: ARCOR® S-16.5 is a solvent free, high functionality epoxy Novolac designed particularly as a protective coating for metals in highly aggressive environments especially high chemical, high abrasion and elevated temperature. Excellent in a wide array of caustics and acids. The ARCOR® S-16.5 multi-functional chemistry produces an excellent coating suited for aggressive service and is suitable for immersion in a wide array of chemicals. ARCOR® S-16.5 can be applied up to 40 mils without slump.
FOR INDUSTRIAL USE ONLY
SPECIFICATION DATA:
TEMPERATURE: Immersion service Max.250ºF(177ºC);
Spike to 350ºF (3 hrs.) Recommended force cure at 250ºF@ 2 hrs. Dry to 400ºF (190C); Spike to 500ºF (246C) (3 hrs.)
Temperature resistance will vary depending on chemical exposure. Consult ARCOR.
SOLIDS BY VOLUME: 100%
VISCOSITY: 65,000 – 85,000 cps
POT LIFE: 20 MIN/Gal @ 72ºF (22.2ºC)
MIX RATIO: 2:1 by Volume (Base : Activator) 100 gm : 50 gm by weight
COLOR: Blue, Light Gray, Gray
ABRASION: Excellent
FLEXIBILITY: Very Good. Excellent with Polyester or Fiberglass Mat; 1.5 oz/ft2 (.5 KG/M2)
APPLICATIONS: Neutralization Tanks, Caustic Tanks, Clarifiers, Demin Tanks, Chemical Drain Troughs, Secondary Containment, Pumps. FGD; Outlet Ducts, Absorbers, I.D. Fans, Scrubbers. Barge Tanks. Separators. Pumps. Low coefficient of Friction improves flow. Industrial Floorings. For the most aggressive applications we recommend Force Cure at 250ºF(121.1ºC) @2 hrs. Product can be force cured in service, consult ARCOR.
SHELF LIFE: 5 Years at 55-95ºF (13-35ºC)
COVERAGE: 1604/#mils = ft²/gal/coat; 149/#mils = M2/Gal; 3,785/#microns = M2/Gal; 1mil = 25 micron; 1 Gal = 3.785 L; 10.77ft2 = M2
WEIGHT PER GALLON: 12.6 lbs. (5.7 KG) 3.3 lbs. (1.5 KG)/Liter
FILM THICKNESS:
Spray Application; 1-Coat 20 to 40 mils
Hand Application; 2-3 Coats 15-20 mils per coat
Final DFT Specified by Need; Consult ARCOR
Manufacturer, Novolac Epoxy Technologies Inc., makes no warranty either expressed or implied including warranties of merchantability or fitness for a particular purpose for this product. Under no circumstances will the manufacturer be liable for incidental, consequential or other damages, breach of warranty, strict liability, or any other theory arising out of use of this product. The information and or recommendations contained herein are based on standard Product and are proprietary and furnished solely for the use of our customers. This information is provided in good faith and believed to be true and accurate as of the date/version of this document. As the manufacturer has no control over the use conditions or application process of the parties using this product, the manufacturer cannot accept responsibility for loss, injury or other damages resulting from the use of the Product or this or any other information provided by the manufacturer. Therefore, no guarantees of any kind, expressed or implied, are made by the manufacturer, Novolac Epoxy Technologies Inc., regarding this, or any, product manufactured by them or any contracted or licensed manufacturer. ARCOR® epoxy products do not provide structural integrity or improvement. They are only used to provide protection from corrosion, wear, abrasion and chemical attack on a given substrate and only to the extent provided for in the Data Sheets, Technical Data Sheets, Safety Data Sheets and any other information as supplied in writing directly from manufacturers technical support.
APPLICATION SHEET
REVISED 3/2019
SEE MATERIAL SAFETY DATA SHEET (SDS) BEFORE HANDLING THIS PRODUCT
ChemTel ERS / MOD Tel US: 800-255-3924; Outside US: +1-813-248-0585
SURFACE PREPARATION: Steel surfaces are to be abrasive blasted with chloride free abrasive. Exterior applications to SSPC SP-10 Near White metal finish. Immersion applications to SSPC SP-5 White metal 4+ mil profile. Grind flat all burrs, weld seams, radius sharp edges. Fresh blasted ferrous surfaces to be primed with S-20 immediately to prevent oxidation of surface. Concrete surfaces should be degreased if oil and grease contamination is present. Degreased surface shall be high pressure washed, acid etched, and high pressure washed again so surface is clean and free of all grease, oils and surface laitance. Existing coatings should be abrasive blasted to clean concrete. Prime with EE-10.
MIXING: Thoroughly mix Activator into Base with mixing stick or drill with low speed mixing blade scraping sides and bottom of container or mixing board. Mix by Volume 2-parts Base to 1-part Activator. Or by weight 100 grams Base to 50 grams Activator. Mix thoroughly to produce an even colored and streak-free material.
THINNING: Never thin.
APPLICATION: Brush: medium to stiff bristle of sufficient quality that bristles do not pull out and stick in coating. Trim or tape to <1” nap. Roller: good quality 1/8” nap.
ARCOR Cartridge Sprayer: Heat to 140F(60C). Piston ‘3’; Tip Air ‘3’.
Plural Spray: .029-.035 RAC tip, 3,000-4,500 PSI, Heat to 160ºF Base, 120ºF Activator. Ambient Temperature and Humidity will affect temperature and pressure setting. Consult ARCOR.
Airless Spray: 029-.035 RAC tip, 4,500-5,500 PSI(60:1+). Recommended in-line heater at 120º to 135ºF (Caution: Short Pot-Life). Ambient Temperature and Humidity will affect temperature and pressure setting. Contact ARCOR.
All spray equipment should employ traps to prevent water and oil from contaminating coating and screens to prevent particulate contamination.
APPLICATION TEMPERATURE: Material: Keep between 55 to 95ºF (17 to 35ºC). Substrate: Keep between 45 to 105ºF (7 to 40ºC). The difference in temperature of the substrate and the material should never exceed 10ºF(5ºC). Substrate shall be a minimum of 5ºF(3ºC) above dew point. Do not apply if relative humidity exceeds 90%. If necessary, heat metal prior to surface preparation using electric heater or heat lamp. Never use gas, oil or kerosene heaters as they will leave a greasy residue on metal surface. For best results keep all material in warm area overnight (75ºF+, 24ºC) for ease of mixing. If necessary, base component of material can be heated by microwave for 30-45 seconds for a 1 KG Base unit. If necessary, let material cool before application to allow for more pot life during application.
OVERCOAT / CURE TIME: By brush, roller or squeegee recoat while material is still soft, but tack-free, between 3-12 hours at 77ºF(25ºC). IMPORTANT: If overcoat window is exceeded abrade surface with course sandpaper, grinder or brush blast and wipe with MEK or Acetone. By spray application recoat between 2-12 hours at 77ºF(25ºC). Full cure before immersion recommended 72 hours at 77ºF(25ºC). Add 1 hour’s additional cure time for each 10ºF(-12.2ºC) below 77ºF(25ºC). For highly aggressive environments Force Cure with heat for best performance for 8 hours at 150ºF (66ºC), 2 hours at 250ºF (121ºC).
CLEAN UP: Clean tools immediately after use with M.E.K., Acetone, 98+% Isopropyl Alcohol or similar
WARNING: Base contains epoxy resin. Activator contains alkaline amines, a strong sensitizer. May cause skin irritation, sensitization or other allergic responses. Use with good ventilation, particularly if heated or sprayed. Prevent all contact with skin or eyes. Wear protective clothing, goggles, gloves or barrier creams. Keep containers closed when not in use. Wash thoroughly after handling. In case of skin contact immediately wash with soap and water. In case of eye contact, flush with water for 15 minutes. If irritation persists seek medical attention. Consult the Product Safety Data Sheets (SDS) BEFORE USE!
The information and or recommendations contained herein are based on standard Product and are proprietary and furnished solely for the use of our customers. This information is provided in good faith and believed to be true and accurate as of the date/version of this document. As the manufacturer has no control over the use conditions or application process of the parties using this product, the manufacturer cannot accept responsibility for loss, injury or other damages resulting from the use of the Product or this or any other information provided by the manufacturer. Therefore, no guarantees of any kind, expressed or implied, are made by the manufacturer, Novolac Epoxy Technologies Inc., regarding this, or any, product manufactured by them or any contracted or licensed manufacturer.

Are you interested in this product?
Want to know more?
To place orders and/or obtain pricing information contact or call our offices below:
Manufacturer makes no warranty either expressed or implied including warranties of merchantability or fitness for a particular purpose for this product. Under no circumstances will the manufacturer be liable for incidental, consequential or other damages, breach of warranty, strict liability, or any other theory arising out of use of this product. ARCOR® epoxy products do not provide structural integrity or improvement. They are only used to provide protection from corrosion, wear, abrasion and chemical attack on a given substrate and only to the extent provided for in the Data Sheets, Technical Data Sheets, Safety Data Sheets and any other information as supplied in writing directly from manufacturers technical support.